Honda Powered 8,750 Watt Generator |
|
|
Honda Powered 8,750 Watt - This brand new Industrial Portable generator features a 8,750 watt surge rating and is designed for general use by the professional. This unit is designed for heavy duty service on the job site or as temporary stand-by-power. This unit features a premium 13 HP Honda GX 390 OHV engine w/ a cast-iron cylinder sleeve. This unit features brushless HD alternators with THD less than 6%. This genset is equipped with a frame mounted control panel, automatic voltage regulation, long run 8 gallon fuel tank w/ in-take fuel gauge, ball bearings for long life, super silencer muffler, wheel kit w/ rubber tires & fold down handles, Honda's Low Oil Alert shutdown and is recoil start.
|
| Model Number |
03365 |
| Electrical Specifications |
MLS4-Y |
| Automatic Voltage Regulator |
Voltage Stability +/- 2% Frequency Stability +/- 2% |
| Power Single-Phase |
--- |
| Maximum Output |
8,750 watts |
| Continous Output |
7,000 watts |
| Load Amperage at 120 volts |
--- |
| Maximum Load |
72.9 Amps |
| Continous Load |
58.3 Amps |
| Load Amperage at 240 volts |
--- |
| Maximum Load |
36.5 Amps |
| Continous Load |
29.2 Amps |
| Sound Level @ 23 ft(7 m) at full load |
73 dB(A) |
|
| Model Number |
03365 |
| Engine |
- |
| Type |
Honda GX 390 |
| Power |
13 HP |
| Oil Capacity |
Approx. 1.2 Qts |
| Cylinder Block |
Aluminum w/ Cast Iron Sleeve |
| Displacement |
389 cc |
| Exhaust Outlet |
1 3/4" OD Muffler Outlet |
| Cooling System |
Air-cooled |
| Fuel |
Unleaded Gasoline |
| Starting System |
Recoil |
|
| Model Number |
03365 |
| Consumption |
- |
| Consumption at 1/2 load |
0.625 gallons/hour |
| Consumption at 3/4 load |
0.72 gallons/hour |
| Consumption at full load load |
0.89 gallons/hour |
| Fuel Tank Capacity |
8 Gallons - Fuel Gauge Included |
| Run Time at 1/2 Load |
12.8 Hours |
| Model Number |
03365 |
| Receptacles |
- |
| 120 V Duplex NEMA#5-20R |
2-15 Amp |
| 120/240 V Twistlock NEMA#14-30R |
1-30 Amp |
| Circuit Breaker Protection |
Standard |
| Circuit Breaker Protection (resetable) at each outlet |
| Model Number |
03365 |
| Installation Specifications |
- |
| Exhaust Outlet |
1 3/4" OD Muffler Outlet |
Exhaust Location & Direction (Facing Engine) |
Left-Side |
Service Points (Facing Engine) |
Oil Fill: Right-Side Air Filter: Front-Side Spark Plug: Left-Side |
Power Output Location (Facing Engine) |
Right-Side |
| Minimum Cord Size |
0-50 Feet: 10 AWG 51-100 Feet: 8 AWG 101-150 Feet: 6 AWG |
| Engine Oil Type |
10W-30 Synthetic |
| Model Number |
03365 |
| Warranty |
- |
| Engine Warranty |
2 Years |
| Generator Warranty |
2 Years |
| 100% Coverage for Parts & Labor |
Standard |
| Model Number |
03365 |
| Dimensions |
- |
Without Wheel Kit (L x W x H) |
30.5" x 19.7" x 21.7" |
With Wheel Kit (L x W x H) |
30.5" x 27" x 26.7" |
| Dry weight |
195 lbs |
| | |